Start Up
Instructions |
 |
Step 1 - Find Back Flow Prevention Valve Assembly
(shown)
Step 2 - Close Outlet Valve Handle and Inlet Valve Handle
Turning Clockwise until perpendicular to pipe. NOTE:
Both Outlet & Inlet Valve Handles are shown in open
position. Turn Clockwise 90 degrees from position shown to
close. |
Step 3 - Close Bleed Screws - Use flat head screwdriver to turn
screws 90 degrees to the right to close. NOTE: see
pictures
 |
CLICK ON
PHOTO TO SEE BLEED SCREW IN OPEN POSITION |
 |
CLICK ON
PHOTO TO SEE BLEED SCREW IN CLOSED POSITION |
|
Step 4 - Close spigot or insert plug.
Step 5 - Turn on water supply for system in basement. Valve handle
located near main water supply or near exit from building to back flow
prevention valve assembly. |
Step 6 - Open inlet valve
handle. Water will rush to bonnet, snapping closed the check
spring for back flow. NOTE: Water will leak out of bonnet for a few
moments until check spring closes.
Step 7 - Open Outlet Valve SLOWLY Water should rush
to system.
Step 8 - Turn on controller in garage and cycle the system, checking all
zones for proper system operation. |
 |
|
HINT
All FVI systems are put in with a rain sensor (shown left). During a
wet spring, you may need to bypass your rain sensor in order to check
system operation. To bypass rain sensor turn cap so indicator on cap meets
with indicator on body of rain sensor (much like lining up the arrows on a
child safe medicine bottle) and lift to separate. This disables the
kill switch and lets operation of system.
IF YOU HAVE ANY QUESTIONS RELATED TO THIS OR HAVE ANY SYSTEM PROBLEMS
OR CONCERNS PLEASE CONTACT FVI, INC. - (920) 437-7990 |